Last edited by Faeshicage
Tuesday, July 7, 2020 | History

3 edition of A 3-component laser-doppler velocimeter data acquisition and reduction system found in the catalog.

A 3-component laser-doppler velocimeter data acquisition and reduction system

A 3-component laser-doppler velocimeter data acquisition and reduction system

  • 361 Want to read
  • 19 Currently reading

Published by National Aeronautics and Space Administration, Ames Research Center, For sale by the National Technical Information Service in Moffett Field, Calif, [Springfield, Va .
Written in English

    Subjects:
  • Data acquisition.,
  • Data reduction.,
  • Laser doppler.,
  • Velocimeters.

  • Edition Notes

    Other titlesThree component laser doppler velocimeter data acquisition and reduction system.
    StatementL.C. Rodman, J.H. Bell, R.D. Mehta.
    SeriesNASA contractor report -- 177390., NASA contractor report -- NASA CR-177390.
    ContributionsBell, J. H., Mehta, R. D., Ames Research Center.
    The Physical Object
    FormatMicroform
    Pagination1 v.
    ID Numbers
    Open LibraryOL15415861M

    Flow Visualization: Techniques and Examples Laser beam Cylindrical lens ~ Camera Fig. Typical experimental setup of the electrolytic precipitation technique. iron, lead, tin, and brass may be used as an anode, soft solder, such as lead-free solder, is found to produce the "best" smoke. Several flow phenomena mentioned above for a 3 component airfoil in high lift configuration can be seen (separation on the slat lower side, slat wake and main body boundary layer interaction, main body cove separation, slat wake-main body wake and flap boundary layer interaction,..). 53 Fig. 8. .

    Data Acquisition PXI-based control data system with channel A/D and digital I/Os; remote field point with temperature RTD inputs and 8-channel A/D; axis motion control system with programmable PID; client data system: PXI-based with 96 digital I/Os, channel A/D with programmable signal conditioning system. Book of Abstracts of the International Congress on Ultrasonics, May , Metz, France. Congress hosted by Georgia Tech Lorraine in Collaboration with the French Acoustical Society. Congress.

    Subsequent image processing, image interrogation, analysis, and data reconstruction add to data uncertainty. Nonetheless, a state-of-the-art planar PIV system is capable of recording images that yield typically measurements of the velocity (per image frame pair) with an accuracy of approximately 1–2% of the full-scale displacement : Madhavan K T (), Development of data processing techniques for laser Doppler velocimeter based flow measurements, Ph.D. Thesis, IISc, Bangalore. Goldstein R J and Kreid D K (), Measurement of laminar flow development in a square duct laser Doppler flowmeter, ,Vol, pp


Share this book
You might also like
Saint Ives in Cambridgeshire

Saint Ives in Cambridgeshire

Meanings

Meanings

QUANTITATIVE methods in management

QUANTITATIVE methods in management

Anglo-Saxon poems of Beowulf ; The travellers song ; and, The battle of Finnesburh

Anglo-Saxon poems of Beowulf ; The travellers song ; and, The battle of Finnesburh

Devil may cry

Devil may cry

Business plan for retailers.

Business plan for retailers.

Cestoda.

Cestoda.

Recent advances in analytical chemistry

Recent advances in analytical chemistry

Modern and fossil Peridiniineae

Modern and fossil Peridiniineae

Studies in evolution and biology

Studies in evolution and biology

Scheduled civil aircraft emission inventories for 1976 and 1984

Scheduled civil aircraft emission inventories for 1976 and 1984

Law & the sacred

Law & the sacred

Anne

Anne

How to Master the Art of Selling

How to Master the Art of Selling

IBM H-series forecast

IBM H-series forecast

Education in Northern Ireland

Education in Northern Ireland

Great sermons on the birth

Great sermons on the birth

A 3-component laser-doppler velocimeter data acquisition and reduction system Download PDF EPUB FB2

A 3-component laser-doppler velocimeter data acquisition and reduction system (SuDoc NAS ) [L. Rodman] on *FREE* shipping on qualifying : L. Rodman. Get this from a library.

A 3-component laser-doppler velocimeter data acquisition and reduction system. [L C Rodman; J H Bell; R D Mehta; Ames Research Center.].

A 3-component laser-Doppler velocimeter data acquisition and reduction system eBook: National Aeronautics and Space Administration NASA: : Kindle Store Skip to main content.

Try Prime Hello, Sign in Account & Lists Sign in Account & Lists Author: National Aeronautics and Space Administration NASA. Buy A 3-component laser-doppler velocimeter data acquisition and reduction system (SuDoc NAS ) by L. Rodman (ISBN:) from Amazon's Book Store.

Everyday low prices and free delivery on eligible : L. Rodman. An experimental comparison method is proposed for the verification of mean flow and turbulence measurements obtained with a three-dimensional laser Doppler velocimeter system.

Such measurements can include large errors caused by problems unique to three-dimensional systems. Direct comparisons of laser and hot cross-wire measurements obtained in two-dimensional flows, as is the Cited by: 2.

Updated daily. Explore all research articles, conference papers, preprints and more on ASSEMBLY LANGUAGE. Find methods information, sources, references or conduct a. The measurement by a 3-d laser Doppler velocimeter of a turbulent flow has been numerically simulated.

Errors associated with the probe volume geometry and the coincidence time window concept are by: 8. turbines, are considered.

In these cases optical access problems are most severe and standard 3-component velocimeter arrangements which need a solid angle of 30 to 40 degrees for optical access can not be applied.

A specially designed 3-component L2F system, see Schodl (), is on the market today and in use at different European institutions. to the data acquisition and reduction units by the receiving A miniature three-component LDV probe –0. A sub-miniature Laser-Doppler Velocimeter(LDV) system was developed to make.

The acquired information, such as the development of boundary and shear layer and transient vortex structure, is consistent with the measured data of wall pressure and visualization images of the flame, and shows a good agreement with Laser Doppler Velocimeter (LDV) by: 1.

Washington, DC: The National Academies Press. doi: / These measurements were obtained with a three-component Laser Doppler Velocimeter. SCALING OF THE FREE SURFACE JET Rajaratnam and Humphries () studied the mean flow characteristics of free surface jets when the free surface is located at the edge of the jet nozzle.

Laser Doppler Velocimetry (LDV) is a compliment to PIV and is used for non-intrusive, time-resolved (kHz), point measure­ments of local fluid velocities and their fluctuations. Figure 1. A combined PIV-image (flow field) and OH-LIF (Laser Induced Fluorescence) image.

Final data reduction/analysis: As described above, the data reduction program should be verified, and the initial data plotted together with the pretest estimates before leaving the test. In most facilities the only difference between the data available on site during the test and the final data is due to the use of more elaborate averaging.

Suggested Citation:"Prediction of High Reynolds Number Flow Around Naval Vessels."National Research Council. Twenty-Fourth Symposium on Naval gton, DC: The National Academies Press. doi: / A 3-component laser-Doppler velocimeter data acquisition and reduction system (English Edition) eBook: National Aeronautics and Space Administration NASA: : Kindle-ShopFormat: Kindle.

Achetez et téléchargez ebook A 3-component laser-Doppler velocimeter data acquisition and reduction system (English Edition): Boutique Kindle - Science: Passer au contenu Essayez Prime Bonjour, Identifiez-vous Compte et listes Identifiez-vous Compte et listes Retours et Commandes Testez Prime Panier.

Appareils Amazon Format: Format Kindle. This banner text can have markup. web; books; video; audio; software; images; Toggle navigation. Laser Doppler velocimeter system simulation for sensing aircraft wake vortices.

Part 2: Processing and analysis of LDV data (for runs and ) NASA Technical Reports Server. Laser velocimeter (autocovariance) buffer interface.

NASA Technical Reports Server (NTRS) Clemmons, J. I., Jr. A laser velocimeter (autocovariance) buffer interface (L. Mechanical Engineering. Reference to this book ICU International Congress on Ultrasonics Abstract Book, Metz, France, Declercq N. F. editor () Publication year Acknowledgement The compilation of this book has been made possible with the help of Didier Cassereau, Bertrand Dubus and John Fritsch with support from the Scientific and Technical Committee of.Intro - SciTech 5–9 JANUARY The Largest Event for Aerospace Research, Development, and Technology FINAL PROGRAM #aiaaSciTech KISSIMMEE, FL WHAT’S IMPOSSIBLE TODAY WON’T BE TOMORROW.

AT LOCKHEED MARTIN, WE’RE ENGINEERING A BETTER TOMORROW.ICU International Congress on Ultrasonics Abstract Book, Metz, France, Declercq N.

F. editor () - Free ebook download as PDF File .pdf), Text File .txt) or read book online for free. Book of Abstracts of the ICU International Congress on Ultrasonics, MayMetz, France. Congress hosted by Georgia Tech Lorraine in collaboration with the French Acoustical Society.